X-RAY DIFFRACTION Experimental Data & Validation


X-ray Experimental Help

Crystallization

Crystalization Experiments
pH 6.4
Details pH 6.4

Crystal Data

Unit Cell
Length (Å) Angle (°)
a = 102.6 α = 90
b = 67.39 β = 131.63
c = 98.81 γ = 90
Symmetry
Space Group C 1 2 1

Diffraction

Diffraction Detector
Detector Diffraction Type Details Collection Date
AREA DETECTOR SIEMENS X1000 -- 1994-11-01
Diffraction Radiation
Monochromator Protocol
-- --
Diffraction Detector Source
Source Type Wavelength List Synchrotron Site Beamline
-- -- -- -- --

Data Collection

Overall
Resolution (High) Resolution (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
-- -- 96.0 0.053 -- -- 2.02 -- 28288 -- 0.0 --

Refinement

Statistics
Structure Solution Method Refinement High Resolution Refinement Low Resolution Cut-off Sigma (I) Cut-off Sigma (F) Number of Reflections (All) Number of Reflections (Observed) Number of Reflections (R-Free) Percent Reflections (Observed) R-Factor (All) R-Factor (Observed) R-Work R-Free R-Free Selection Details
-- 2.1 12.0 -- 3.0 -- 22154 -- 75.5 -- -- 0.208 -- --
Temperature Factor Modeling
Temperature Factor Value
Mean Isotropic B 41.7
RMS Deviations
Key Refinement Restraint Deviation
x_angle_deg 1.81
x_bond_d 0.014
Number of Non-Hydrogen Atoms Used in Refinement
Non-Hydrogen Atoms Numbers
Protein Atoms 4010
Nucleic Acid Atoms 0
Heterogen Atoms 0
Solvent Atoms 105

Software

Software
Software Name Purpose
XENGEN data collection version: 3.1
X-PLOR model building version: 3.1
X-PLOR refinement version: 3.1
XENGEN data reduction
X-PLOR phasing version: 3.1