SOLUTION NMR Experimental Data


Experimental Details
Sample Conditions
Spectrometer Information
Manufacturer Model Field Strength
Bruker ARX-500 500.0
NMR Refinement
Method simulated annealing
Details 50 INITIAL STRUCTURES WERE CALCULATED USING A SIMULATED ANNEALING PROTOCOL WITHIN THE PROGRAM X-PLOR. THESE STRUCTURES WERE THEN ENERGY MINIMIZED USING 1000 CYCLES OF CONJUGATE GRADIENT MINIMIZATION WITH A REFINED FORCEFIELD BASED ON THE PROGRAM CHARMM [BROOKS ET AL. (1983) J. COMPUT. CHEM., 4, 187-217].
NMR Ensemble Information
Conformer Selection Criteria LOWEST ENERGIES AND LEAST NUMBER OF RESTRAINT VIOLATIONS
Conformers Calculated Total Number 50
Conformers Submitted Total Number 20
Computation: NMR Software
# Classification Software Name Author
1 refinement version: 3.1 X-PLOR BRUNGER
2 structure solution X-PLOR --