SOLUTION NMR Experimental Data


Experimental Details
Sample Conditions
Sample ContentsTRIS
Solventn/a
Ionic Strength50 mM KCL
pH7.0
Pressure1
Temperature (K)300
Experiment(s):NOESY, PECOSY, TOCSY, ROESY, QUIET-NOESY
Spectrometer Information
Manufacturer Model Field Strength
Varian INOVA 500.0
Varian UNITY 400.0
NMR Refinement
Method matrix relaxation
NMR Ensemble Information
Conformer Selection Criteria AVERAGE OF 5 STRUCTURES THAT THE NOESY BACKCALCULATION AGREES WITH EXPERIMENTAL NOESY
Conformers Calculated Total Number 100
Conformers Submitted Total Number 1
Additional NMR Experimental Information
1 100MS NOESY, 250MS NOESY 250MS QUIETNOESY 70MS BAND-SELECTIVE J TOCSY FOR PHOSPHOROUS "J SCALE" SET TO 2 AND 3
Computation: NMR Software
# Classification Software Name Author
1 refinement version: 3.1 X-PLOR BRUNGER
2 structure solution VNMR --