3JBF

Complex of poliovirus with VHH PVSP19B


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg6.774
r_dihedral_angle_4_deg3.175
r_dihedral_angle_3_deg2.354
r_angle_refined_deg2.103
r_dihedral_angle_1_deg0.297
r_chiral_restr0.167
r_bond_refined_d0.01
r_gen_planes_refined0.001
Sample
Nanobody PVSS8A in complex with poliovirus P1/Mahoney
Sample Components
Human poliovirus 1
PVSP19B
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentHOMEMADE PLUNGER
Cryogen NameETHANE
Sample Vitrification DetailsBlotted for 4 seconds before plunging into liquid ethane (homemade plunger).
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles18009
Reported Resolution (Å)4.8
Resolution MethodFSC 0.143 CUT-OFF
Other Details(Single particle details: The particles were processed using Frealign.) (Single particle--Applied symmetry: I)
Refinement Type
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1 (1I3U)
Refinement SpaceRECIPROCAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetML agreement with Fourier amplitudes and phases
Overall B Value
Fitting Procedure
DetailsREFINEMENT PROTOCOL--flexible DETAILS--Using stereochemically and icosahedrally restrained maximum likelihood refinement in REFMAC5, a representative ...REFINEMENT PROTOCOL--flexible DETAILS--Using stereochemically and icosahedrally restrained maximum likelihood refinement in REFMAC5, a representative subset of the full atomic model with all neighbors present was built and refined to fit the corresponding subset of the experimental map. Portions of the model whose density resembled a structural homolog were identified and restrained to agree with the homolog. Detailed atomic models were constructed in areas of difference wherever the resolution of the map permitted. The Fourier-amplitude-weighted average cosine of the phase discrepancy was tracked.
Data Acquisition
Detector TypeGATAN K2 (4k x 4k)
Electron Dose (electrons/Å**2)25
Imaging Experiment1
Date of Experiment2013-11-27
Temperature (Kelvin)80
Microscope ModelFEI POLARA 300
Minimum Defocus (nm)-1400
Maximum Defocus (nm)-4000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.26
Imaging ModeBRIGHT FIELD
Specimen Holder ModelOTHER
Nominal Magnification23000
Calibrated Magnification25381
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsGatan K2 operated in Super-resolution mode
EM Software
TaskSoftware PackageVersion
MODEL FITTINGCoot
MODEL FITTINGREFMAC5
MODEL FITTINGSPDBV
RECONSTRUCTIONFREALIGN
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
per particle